Phone

0823 1173 8960 (Fajar)

0857 4065 2657 (Mashudy)

Phone Office

+62-21 29563045







Acuvim II Power Meter with Data Logging

Acuvim II Power Meter with Data Logging



Inquiry Catalog

Description

  • Power Meter with Datalogging Records Voltage, Current, Amperage, Frequency, Power (Reactive, Apparent, Active), Energy, Power Factor, Peak Demand, Run Time, THD and Individual Harmonics
  • 16 Different Alarm Parameters for Alerts
  • Various I/O Modules Available for Digital Inputs/Outputs, Analog Inputs/Outputs and Relay Outputs
  • Compatible with Single or Three-Phase Electrical Systems up to 600 Volts AC
  • View Data and Charts Online in a Browser and Receive Email Notifications with Optional Ethernet Communications Module
  • Modbus, Ethernet and Profibus Communication Ports Available
  • ±0.2% Accuracy with ANSI C12.20 Standard for Revenue Grade Meters

Feature

Includes AcuView Software for Remote Meter Access and Control, Real-Time Monitoring and local PC Logging


Spesification

Voltage Range: 20 Volts to 500 kiloVolts
Accuracy: 0.2%
Resolution: 0.1 Volts
Current Range: 5 mA to 50,000 Amps 
Accuracy: 0.2%
Resolution: 0.001 Amps
Power Range: -9999 MW to 9999 MW 
Accuracy: 0.2%
Resolution: 1 Watt
Reactive Power Range: -9999 MVar to 9999 MVar
Accuracy: 0.5%
Resolution: 1 Var
Apparent Power Range: -9999 MVA to 9999 MVA 
Accuracy: 0.2%
Resolution: 1 VA
Power Demand Range: -9999 MW to 9999 MW 
Accuracy: 0.2%
Resolution: 1 W
Reactive Power Demand Range: -9999MVar to 9999MVar 
Accuracy: 0.2%
Resolution: 1 Var
Apparent Power Demand Range: -9999 MVA to 9999 MVA
Accuracy: 0.2%
Resolution: 1 VA
Power Factor Range: -1.000 to 1.000 
Accuracy: 0.2%
Resolution: 0.001
Frequency Range: 45.00 Hz to 65.00 Hz 
Accuracy: 0.2%
Resolution: 0.01 Hz
Energy (Primary) Range: 0 to 99999999.9 kWh
Accuracy: 0.2%
Resolution: 0.1 kWh
Energy (Secondary) Range: 0 to 999999.999 kWh
Accuracy: 0.2%
Resolution: 0.001 kWh
Reactive Energy (Primary) Range: 0 to 99999999.9 kVarh
Accuracy: 0.2%
Resolution: 0.1 kvarh
Reactive Energy (Secondary) Range: 0 to 999999.999 kVarh
Accuracy: 0.2%
Resolution: 0.001 kvarh
Apparent Energy (Primary) Range: 0 to 99999999.9 kVAh
Accuracy: 0.2%
Resolution: 0.1 kVAh
Apparent Energy (Secondary) Range: 0 to 999999.999 kVAh
Accuracy: 0.2%
Resolution: 0.001 kVAh
Harmonics Range: 0 to 100% 
Accuracy: 2.0%
Resolution: 0.1%
Phase Angle Range: 0° to 359.9°
Accuracy: 2.0%
Resolution: 0.1°
Unbalance Factor Range: 0 to 100% 
Accuracy: 2.0%
Resolution: 0.1%
Running Time Range: 0 to 9999999.99h 
Resolution: 0.01h
Current Inputs
(Each Channel)
Nominal Current: 5A ac
Metering Range: 0 to 10 A ac
Withstand: 20 Arms (Continuous); 100 Arms (1 Sec., non-recurring)
Burden: 0.05VA (typical) @ 5Arms
Pickup Current: 0.1% of Nominal
Accuracy: 0.2% Full Scale
Voltage Inputs
(Each Channel)
Nominal Full Scale: 400 Vac L-N, 690 Vac L-L
Withstand: 1500Vac (Continuous); 3250 Vac, 50/60 Hz (1 min.)
Input Impedance: 2Mohm per phase
Metering Frequency: 45 Hz to 65 Hz
Pickup Voltage: 30Vac
Accuracy: 0.2% Full Scale
Energy Accuracy Active: Class 0.2S (According to IEC 62053-22) 
Reactive: Class 2 (According to IEC 62053-23)
Harmonic Resolution Metered Value: 63rd Harmonic
AC/DC Control Power Operating Range: 100-415 Vac, 50/60 Hz; 100-300 Vdc 
Burden: 5W 
Frequency: 50/60 Hz 
Withstand: 3250 Vac, 50/60 Hz for 1 Minute
Installation Category III (Distribution)
Low Voltage DC Control Power (Optional) Operating Range: 20 to 60 Vdc 
Burden: 5W
Digital Input (DI) Input Voltage Range: 20 to 220 Vac/dc
Input Current (Max): 2mA
Start Voltage: 15 Volts
Stop Voltage: 5 Volts
Pulse Frequency (Max): 100 Hz, 50% Duty Ratio (5ms ON and 5ms OFF)
SOE Resolution: 2 ms
Digital Output (DO)
(Photo-MOS)
Voltage Range: 0 to 250 Vac/dc
Load Current: 100mA (Max) 
Output Frequency: 25 Hz, 50% Duty Ratio (20ms ON and 20ms OFF)
Isolation Voltage: 2500 Vac
Relay Output (RO) Switching Voltage: 250 Vac, 30Vdc (Max) 
Load Current: 5A (R), 2A (L) 
Set Time: 10ms (Max) 
Contact Resistance: 30mΩ (Max)
Isolation Voltage: 3000 Vac
Mechanical Life: 1.5 x 107
Analog Output (AO) Output Range: 0 to 5 Volts; 1 to 5 Volts; 0 to 20mA; 4 to 20mA (Optional) 
Accuracy: 0.5% 
Temperature Drift: 50ppm/°C Typical 
Isolation Voltage: 500 Vdc
Open Circuit Voltage: 15 Volts
Analog Input (AI) Input Range: 0 to 5 Volts; 1 to 5 Volts; 0 to 20mA; 4 to 20mA (Optional) 
Accuracy: 0.2% 
Temperature Drift: 50ppm/°C Typical 
Isolation Voltage: 500 Vdc
Power Supply
(Digital Input)
Output Voltage: 24 Volts DC 
Output Current: 42 mA 
Load: 21 Digital Inputs (Max)
Data Storage Capacity 4MB of Internal Memory for Data Logging
Communications RS-485 (Standard); Ethernet, PROFI-BUS (Optional)
RS-485 Communications Protocol: MODBUS RTU (Industry Standard) 
Type: 2 Wire Connection 
Baud Rate: Up to 38,400
Ethernet Communications
(Optional)
10M/100M BaseT 
MODBUS RTU Protocol
Data Browsing Through HTTP 
Sending E-mail Automatically
PROFI-BUS Communications
(Optional)
PROFIBUS RTU Protocol
Works as PROFIBUS Slave, Baud Rate Adaptive, Up to 12M
Typical Input Bytes: 32
Typical Output Bytes: 32
PROFIBUS Standard According to EN 50170 Vol. 2
Display LCD Screen Display with White Back Light
Wide Environmental Temperature Endurance
Displays Load Percentage, 4 Quandrants Power and Load Nature
Alarms Up to 16 Parameters Set with Time Interval
Events Recorded with Time Stamps and Triggers Alarm DO Output
(44 Different Parameters Available)
Operating Range Temperature: -25°C to 70°C
Humidity: 5% to 95% Non-Condensing
Pollution Degree: 2
Storage Range Temperature: -40°C to 85°C
Humidity: 5% to 95% Non-Condensing
Standards Compliance Measurement: IEC 62053-22; ANSI C12.20
Environmental: IEC 60068-2
Safety: IEC 61010-4; UL 61010-1
EMC: IEC 61000-4/-2-3-4-5-6-8-11; CISPR 22
Outlines: DIN 43700; ANSI C39.1
Dimensions 9.6cm x 9.6cm x 5.07cm (3.8" x 3.8" x 2.0")