Description

TandD Logger Measuring and Recording Carbon Dioxide, Temperature and Humidity


Feature

  • Measures and Records Carbon Dioxide (CO2), Temperature and Humidity in Indoor Environments
  • 0 to 5,000 ppm (CO2), -30°C to 80°C (Temp) and 0 to 999% RH (Humidity) Measurement Ranges
  • Programmable Alarms and Contact Closure Output
  • Large LCD Display will Cycle Through all Three Measurements
  • Perfect for Air Quality Monitoring and IAQ Auditing

Spesification

Data Channels1 Carbon Dioxide Channel (Internal)
1 Temperature Channel (External)
1 Humidity Channel (External)Carbon DioxideRange: 0 to 5,000 ppm (Display Range Up to 9,999 ppm) 
Accuracy: ±50 ppm + 5% of Reading @ < 5,000 ppm 
Resolution: 1 ppm 
Response Time: 15 Minutes (to 90%)
Sensor: NDIR (Non-Dispersive Infrared)TemperatureRange: -30°C to 80°C (-22°F to 176°F)
Accuracy: ±0.3°C (10°C to 40°C); ±0.5°C (Remainder)
Resolution: 0.1°C
Response Time: 7 Minutes (to 90%)
Sensor: Platinum ResistanceHumidityRange: 0 to 99% RH 
Accuracy (10% to 85%): ±2.5% RH @ 25°C
Accuracy (Rest of Range): ±4.0% RH @ 25°C
Resolution: 0.1% RH 
Response Time: 7 Minutes (to 90%)
Sensor: Electrostatic Capacitance TypeData Storage Capacity8,000 Carbon Dioxide, Humidity and Temperature ReadingsSampling Interval1, 2, 5, 10, 15, 20, 30 Seconds
1, 2, 5, 10, 15, 20, 30, 60 Minutes
(User-Configurable)Recording ModesEndless: Overwrites When Capacity is Full
One-Time: Stop Recording When Capcity is FullLCD DisplayRecording Status, Amount of Recording Data, Communication Status, Recording Mode, Battery Level, Measurements, Unit of MeasurementAlarmContact Closure Output, Open Drain Output (Voltage when Off: DC Less than 30 Volts; Current when ON: Less than 0.1 Amps; Resistance when ON: About 15Ω)Power SourceAC Power (Adapter Included)
(4) AA Alkaline Battery (User-Replaceable)Battery LifeApproximately 2 Days @ 25°CBattery ClassificationAlkalineData DownloadUSB: 45 Seconds for 8,000 Samples/Readings 
Infrared: 60 to 80 Seconds for 8,000 Samples/ReadingsInterfaceUSB Communications (USB Cable Included)
Serial Communications
Infrared Communications (Requires #TR-57DCI)Software CompatibilityMS Windows 7 (32 & 64 Bit), Vista and XP (32 Bit)Standards ComplianceCE, RoHSOperating EnvironmentTemperature: -30°C to 80°C (-22°F to 176°F)
Humidity: 90% RH or Less (Non-Condensing)Weight214 grams (7.5 oz.)Dimensions96mm x 66mm x 46mm (3.8" x 2.6" x 1.8") w/o External Temp/RH Sensor