CR1000 Measurement and Control Datalogger

CR1000 Measurement and Control Datalogger



Order Catalog

Description

The CR1000 consists of a measurement and control module and a wiring panel. This datalogger uses an external keyboard/display and power supply. Low power consumption allows the CR1000 to operate for extended time periods on a battery recharged with a solar panel—eliminating the need for AC power. The CR1000 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.

The CR1000's module measures sensors, drives direct communications and telecommunications, reduces data, controls external devices, and stores data and programs in on-board, non-volatile storage. The electronics are RF shielded and glitch protected by the sealed, stainless-steel canister. A battery-backed clock assures accurate timekeeping. The module can simultaneously provide measurement and communication functions. The on-board, BASIC-like programming language supports data processing and analysis routines.


Spesification

Maximum Scan Rate: 100 Hz
Analog Inputs: 16 single-ended or 8 differential individually configured
Pulse Counters: 2
Switched Excitation Channels: 3 voltage
Digital Ports1: 8 I/Os or 4 RS-232 COM2
Communications/Data Storage Ports: 1 CS I/O, 1 RS-232, 1 parallel peripheral
Switched 12 Volt: 1
Input Voltage Range: ±5 Vdc
Analog Voltage Accuracy: ±(0.06% of reading + offset), 0° to 40°C
Analog Resolution: 0.33 µV
A/D Bits: 13
Power Requirements: 9.6 to 16 Vdc
Dimensions: 23.9 x 10.2 x 6.1 cm(9.4" x 4.0" x 2.4")
Dimensions with CFM100 or NL115 attached: 25.2 x 10.2 x 7.1 cm (9.9" x 4.0" x 2.8")
Weight: 1.0 kg (2.1 lb)
Protocols Supported: PakBus, Modbus, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM
CE Compliance Standards to which Conformity is Declared: IEC61326:2002
Warranty: 3 years

Temperature Range
Standard: -25° to +50°C
Extended: -55° to +85°C

Memory
Operating System: 2 MB flash
Battery-Backed SRAM for CPU Usage and Final Storage: 4 MB
Flash Disk (CPU) for Program Files: 512 kB

Typical Current Drain @ 12 Vdc
Sleep Mode: < 1mA
Active (w/o RS-232 communication): 1 to 16 mA typical
Active (w/RS-232 communication): 17 to 28 mA typical