The EL-IOT-1 is a wireless, Cloud-connected temperature data logger. It comes with an internal sensor with a -20°C to 60°C measurement range. Handy status indicators on the front of the device alert you, at a glance, to alarms, battery levels, and WiFi connection strength.
The device is simple to set up and once configured the device can be placed anywhere within range of your WiFi network, continually monitoring and recording your data to the EasyLog Cloud. You can then use the Cloud to access, analyse, and share your data from any internet-connected device.
Set high and low-temperature alarms where an alarm is activated if your temperature threshold is breached. Alarm options include email alerts (which can be sent to one or multiple email addresses), sounder alerts and light flash alerts.
This product complies with BS EN 12830:2018 (Temperature recorders for the transport, storage, and distribution of temperature-sensitive goods).
- Our lowest cost WiFi temperature data logger
- Measurement range -20 to +60°C
- Uploads data to the EasyLog Cloud
- Status indicators and sounder
- Set up your own alarms and notifications
- Typical battery life over 1 year, or can be permanently powered
The EL-IOT is simple to set up and once configured the device can be placed anywhere within range of your WiFi network, continually monitoring and recording your data to the EasyLog Cloud. You can then use the Cloud to access, analyse and share your data from any internet-connected device worldwide.
The EL-IOT can be set with high and low alarms. If one of your parameters is breached, an instant alarm is activated. Alarm options include email alerts (which can be sent to one or multiple email addresses), SMS messages, and indicator and sounder alerts on the device. Audit marks can be created in the data at the touch of a button.
The device can be powered using the batteries supplied or with a mains adapter (sold separately), and is provided with a wall mountable bracket for easy installation.
Spesification
Temperature Measurement Range |
-20°C to +60°C (-4°F to +140°F) |
Resolution |
0.1°C |
Accuracy |
±0.5°C (±0.9°F) |
Logging Period |
10 seconds to 12 hours (user selectable) |
Transmission Interval |
1 minute to 24 hours (user selectable) |
Internal Memory |
300,000 readings |
Battery Life |
>1 year typical |
Battery Type |
4 x AA 1.5V batteries (or via mains adapter) |
Dimensions |
94 x 83 x 31mm |
Operating Temperature Range |
-18°C to +55°C (0°F to +131°F) (batteries) -20°C to 60°C (-4°F to +140°F) (power supply) |
Environmental Rating |
IP54 (splash proof) |