Phone

0823 1173 8960 (Fajar)

0857 4065 2657 (Mashudy)

Phone Office

+62-21 29563045







HSPALink 2-Way Logging Transmitter

HSPALink 2-Way Logging Transmitter



Order

Description

Sutron’s Multi-Sensor Input Logger plus Flexible, Economical 2-Way HSPALink now has WiFi capability for complete station set-up & data access.


Feature

  • Easy-to-use Software includes setup program.
  • Terminal strip with screw terminals for I/O and power connections
  • Operates 8-16VDC
  • TCXO real-time clock with battery backup, typical ±5.4 sec/mo
  • Built-in solar panel regulator
  • Support for up to 16 measurements of the following inputs:
    • SDI-12/RS485 (not simultaneously)
    • 5 Analog Inputs:
      • 2 single ended inputs (range 0-5V)
      • 2 differential inputs (range ±39mv, ±312mV, ±2.5V)
      • 1 4-20mA input
    • 2 Digital Inputs. Use for tipping bucket, frequency, & on/off
    • Internal temperature
    • Battery voltage
  • Options to average or accumulate 1-8 measurements.
  • Lightning protection (Gas Tube) on all external inputs.
  • User specified equation on any measurement .
  • User specified alarm detection on any measurement.
  • 2 LED for verification/diagnostics.
  • Log capacity: 240K of data accessible via HSPA & direct connect
  • Switched Battery Output
  • Also operates as a standalone recorder without telemetry
  • USB slave for serial connection to PC (USB port does not support typical USB devices like memory sticks, modems, etc.)
  • RealTime Clock operates with internal lifetime battery.
  • 1 Open collector digital output
  • Switched 12 volt output

Advanced Features

  • Equation processing & multiple level averaging
  • GUI Interface for intuitive programming (See LinkComm)
  • Command-line interface for operation without custom programs
  • Separate schedules for each measurement
  • Upgrade firmware via USB.
  • Supports SDI-12, Analog, 4-20ma input
  • Switched Power Output w/overload protection & Digital Output
  • Gas Tube Protection on Inputs
  • Max min or average computations on measurements
  • LED operational status feedback
  • WiFi access point (IEEE 802.11 b/g) with selectable Auto-Time-Out or Always-On modes

HSPA Telemetry Benefits

  • Periodic transmissions at user-set times with data in user-selectable format (pseudobinary B, C, SHEF & ASCII)
  • Supports primary/secondary stations via HSPA
  • Alarm transmissions as they are detected
  • Diagnostics track data amount sent & telemetry performance
  • Supports up to 2 outputs (1 digital & 1 switched battery) for remote commands
  • Optional message authentication for insuring a trusted source & for messages sent to SutronWIN via HSPA
  • Incoming SMS transmissions if HSPA fails or in place of HSPA
  • Extremely affordable
  • HSPA uses 3.5G cellular technology to provide higher data speeds compared to GPRS

Spesification

  • Measurement Interval
1 second to 24 hours
  • Number of Measurements Supported
16
  • ANALOG Channels
5 total, 2 Single ended, 2 Differential, 1 4-20ma
  • Single-Ended Analog
0-5 V (with respect to ground)
          Number Available 2
          Input Range 0 to 5V (with respect to ground)
          Resolution 0.298 µV
          Noise (p/p) @25C 12.0 µV (p/p)
          Accuracy @25C 0.003% (typ) Midscale 0.004% Max
          Input Impedence > 1 MegOhm @25C
  • Differential Analog
 
          Number Available 2
          Range (SW selectable) ±39mV; Common Mode Voltage Range .3 to 3.9 Volts ±?312mV; Common Mode Voltage Range .3 to 3.9 Volts ± 2.5V ; Common Mode Voltage Range .1 to 4.9 Volt
          Resolution 4.657 nV @ ±39mv scale, 37.25 nV @ ±312mv scale, 298 nV @ ±2.5v scale.
          Noise (p/p) @25C 1.6 µV (p/p) ±39 mv / 312 mv scale 5.0 µV (p/p) ±2.5 v scale
          Accuracy @25C 0.004% max @±2.5v scale
          Input Impedance @25C >5 Meg Ohm 312mV FS Differential
  • 4-20 mA Analog
 
           Range 0-22 mA
           Resolution <1nA
           Accuracy @25C 0.02%
           Loop Power External
           Loop Resistance 200 Ohm
  • DIGITAL INPUTS/ OUTPUTS
 
  • Digital Input 1, 2 Tipping Bucket Type
Switch Contact Type. Pulse Width: 30ms – 120ms. Range: DC to 120 tips/min. (min).
  • Digital Input 1,2 Frequency Type
 
          Minimum Frequency 2.8 Hz
          Maximum Frequency 10 KHz
          Input Range 0-5 V
  • Digital Input 1,2 Counter Type
 
          Maximum Frequency 10 kHz (with no debouncing) 300 Hz (with debouncing)
          Input Range 0- 5 Volts
  • INTERNAL TEMPERATURE
 
          Range  -40 to +60°C
          Accuracy ±3 degrees
  • ELECTRICAL
 
          Input Voltage 8-16VDC 10 V minimum for SDI-12 sensor support. Reverse power protected.
          Current Consumption 0.5mA standby typ (all sensors unpowered) 8 to 20mA active typ
          HSPA Transmission  
          Power Connection 2 position terminal strip
          SDI-12 Port 3 position terminal strip
          Red Warning LED Indicates setup or operation error
          Green Heartbeat LED Indicates unit operating properly
          Earth GND .2” screw terminal
  • ENVIRONMENTAL
          Temperature -40°C to +60°C
          Humidity 0-95% Non-condensing
  • KEY FEATURES
 
  • Clock
Internal real-time clock w/battery backup.
           Accuracy ±9.3 s /month(Max) -40 to +60°C. (First Year)
           Accuracy ±2.4 min /year (Max) -40 to +60°C. (First Year)
           Accuracy ±4.5 min / 10 years (Max) -40 to +60°C. (10 Years)
  • Log Capacity
240,000 readings, flash memory
  • USB Port Connector
Serial Communications / USB port
  Mini-B Male USB connector on logger to be connected to USB Type-A Male (Windows PC). LinkComm software included for USB port communications
  • Internal Solar Panel Battery Charger
5 – 20W Panels. (Max 30 Watts) Automatic charge & float modes protect gel cell & acid batteries.
  • HSPA modem Quad Band HSPA Modem SMA-F Output RF Jack
Modem factory installed, internal with RF output jack for antenna.
  • COMMUNICATIONS
 
          Interfaces 1 USB Mini-B Male (5 pin) Connector Serial Communications – USB. Not full function USB port. HSPA Modem. SDI-12. RS485 (future support)
          SDI-12 interface V1.3 compliant recorder
  Supports up to 16 SDI-12 sensors Automatically combines requests to the same device +12V @ 500mA
  • DIMENSIONS
Operating
          Height 5.3″ (13.5 cm)
          Length 3.8″ (9.7 cm)
          Width 1.3″ (3.4 cm)
          Weight 1 lbs. (.46 kg)
  • DIMENSIONS
Shipping
          Height 14 in. (35.6 cm.)
          Length 10 in. (25.4 cm.)
          Width 6 in. (15.3 cm.)
          Weight 2 lbs. (0.9 Kg)
  • Notes
* Please refer to the X-Link User Manual for full product specifications and variations