Infrared Thermocouple Data Recording Logger

Infrared Thermocouple Data Recording Logger



Order

Description

Madgetech Data Recorder with Type K Infrared Thermocouple for Non-Contact Temperature Measurements


Feature

  • Measure and Record Temperature Using External Type K Infrared Thermocouple Sensor (Included)
  • Increased Accuracy & Response Time With Internal Sensor for Cold Junction Compensation (CJC)
  • 1 Second to 24 Hour User-Selectable Sampling Rate (Configured in Software)
  • Green and Red LED Indicators for Operating Mode and Alarm Thresholds
  • User Replaceable 3.6 Volt Battery with 10 Year Life @ 15 Minute Sampling Rate (Included)

Spesification

Channels (1) Internal Temperature
(1) External Thermocouple Input
Temperature
(Internal)
Sensor Type: Semiconductor
Measurement Range: -40°C to 80°C (-40°F to 176°F)
Accuracy (Calibrated): ±0.25°C (±0.45°F)
Resolution: 0.1°C (0.18°F)
Thermocouple Type: K (Infrared) 
Connection Type: Female Subminiature (SMP), Fixed Screw Terminal or Pluggable Screw Terminal 
Measurement Range: 25°C to 80°C (77°F to 176°F)
Accuracy: ±2.0°C (±3.8°F)
Probe Dimensions: 1.28cm x 1.80 (3.25" x 0.71")
Cable>: 0.9 Meters (36") Length PFA Costed Unshielded Stranded Wire
Cold Junction Cmpensation: Automatic
Resistance: 3000Ω (Max)
Field of View: 60° (1:1) 
Minimum Spot Size: 8 mm (0.3")
Spectral Response: 6.5 to 14 Microns
Data Storage
Capacity
Memory Wrap: 500,000 Total Readings (Memory Wrap) 
Multi Start/Stop Mode: 250,000 Total Readings
Sampling Rate 1 Second to 24 Hours
Start Modes Immediate Start, Delayed Start (up to 18 Months), Multiple Push Button Start/Stop
Multiple Start/Stop
Mode
Start/Stop Data Logger Multiple Times w/o Downloading Data to PC
Stop Modes Manual (via Software) or Timed (Specific Date/Time)
Multiple Start/Stop
Mode Activation
Start: Push Hold Button 5 Seconds Until Green LED Flashes
Stop: Push Hold Button 5 Seconds Until Red LED Flashes
Data Format Date/Time Stamp, °C, °F, K, °R, µV, mV, V
LED Indicators Green: 10 Sec Rate (Logging); 15 Sec Rate (Delayed Start)
Red: 10 Sec Rate (Low Battery/Full Memory); 1 Sec Rate (Alarm Condition)
Alarms Programmable High and Low Alarms with LED Indicator
Alarm Delay: Alarm Activated (via LED) When User-Specified Time Has Lapsed
Trigger Programmable High and Low Limits for Thermocouple Channel. Recording Begins When Trigger is Met.
Multiple Triggers Can be Programmed.
Number of Readings Taken after Triggered Events
Power Source User Replaceable 3.6 Volt Lithium Battery (Included)
Battery Life 10 Years Typical @ 15 Minute Sampling Rate
Dependant Upon Environment and Sampling Rate
Communication Type USB Dongle Connects Data Logger to PC Computer
(Requires #IFC200 USB Interface Package)
Baud Rate 115,200
Housing Enclosure ABS Plastic
Time Accuracy? ±1 Minute/Month @ 20°C
Operating Range Temperature: -18°C to 70°C (-0.4°F to 158°F)
Humidity: 0 to 95% RH (non-condensing)
OS Compatibility Windows 8, 7, Vista and XP (32-bit and 64-Bit)
Weight 0.9 oz (24 grams)
Dimensions 1.4" x 2.2" x 0.6" (3.6 cm x 5.6 cm x 1.6 cm)