Description
TandD Multi-Channel Battery-Operated Thermocouple Recorder with Automatic Data Export to SD Card
Feature
- Measure and Record Temperature Using Type K,J,T,S, or R Thermocouples (Sold Seperately)
- Data Transfered to PC for Analysis Using USB (Cable Included) or SD Card
- Touch Panel for Setup and Configuration Changes in the Field
- LCD Display Shows Current Readings, Trend Graph, Battery Status and Configuration Settings
- Stores up to 240,000 Temperature Readings per Channel (960,000 Total)
Spesification
Thermocouple | Number of Channels: 4 External Inputs for Thermocouples Type: J, K, T, R and S Connection Type: Screwless Terminals Cold Junction Compensation: Automatic Measurement Resolution: 0.1°C Input Impedance: 1MΩ (Approximate) |
Thermocouple Types | Type J: -210°C to 1200°C @ ±0.5°C + 0.3% (Accuracy) Type K: -270°C to 1370°C @ ±0.5°C + 0.3% (Accuracy) Type T: -270°C to 400°C @ ±0.5°C + 0.3% (Accuracy) Type R: -50°C to 1760°C @ ±1.5°C + 0.3% (Accuracy) Type S: -50°C to 1760°C @ ±1.5°C + 0.3% (Accuracy) |
Cold Junction Compensation | Accuracy: ±0.5°C (10°C to 40°C) ; ±0.8°C (Other Ranges) |
Recording Method | Instanteous, Average (Ave), Fine |
Sampling Interval | 100, 200, 500 ms 1, 2, 5, 10, 15, 20, 30 Seconds 1, 2, 5, 10, 15, 20, 30, 60 Minutes |
Data Storage Capacity | Up to 960,000 Readings (1 Channel); Up to 480,000 Readings (2 Channels); Up to 320,000 (3 Channels); Up to 240,000 Readings (4 Channels) |
Recording Mode | Endless: Overwrite Oldest Data when Capacity is Full One-time: Stop Recording when Capacity is Full |
Group Recording | Up to 4 Units (16 Channels) Can Be Recorded Simultaneously |
Start Modes | Immediate or Programmed |
LCD Display | Current Readings, Battery Life and Trend Graph |
Power | (2) AA (Alkaline or Lithium) Battery USB Powered |
Battery Life | At 100ms Sample Rate : 5 Day Typical At 500ms Sample Rate : 7 Day Typical At 1 Second Sample Rate : 7 to 21 Day Typical At 5 Second Sample Rate or Longer : 21 to 60 Day Typical NOTE: Battery Life Depends on Measurement Environment, Sampling Interval and Battery Performance |
Communication Type | USB |
External Storage | SD Memory Card (SDHC Memory Card) - Sold Separately NOTE: Measurement Data Cannot be Directly Recorded onto the Memory Card. Used to Transfer Recorded Data from Data Logger to PC Only. |
Input Terminals | Screwless Terminals Single Wire: 0.32mm to 0.65mm (28 AWG to 22 AWG) Twisted Wire: 0.08 to 0.32mm (28 to 22 AWG). 0.12mm or More in Diameter Strip Length: 9mm to 10mm |
Isolation | CH1, CH2, CH3, CH4, USB are Isolated Max Applied Voltage: ±50 Volts Electrical Isolation Resistance: 50 MΩ or More NOTE: Battery Terminals are Not Isolated from CH1 to Ch4 Input Terminals |
Operating Environment | Temperature: 0°C to 50°C Humidity: 90%RH or Less (No Condensation) |
Weight | 190 grams (Includes Battery) |
Dimension | 120mm x 75mm x 32mm |