Description
Graphtec Recording Device for Voltage, Temp, Humidity, Logic and Pulse w/ Multifunction Input - Expandable up to 200 Input Channels
Feature
- 20 Isolated Input Channels for High Speed Voltage, Temperature, Humidity, Logic/Pulse Recordings
- 10ms Sampling Rate When Limiting the Number of Channels in Use
- Isolated Input System Ensures Signals are Not Corrupted by Other Channels
- Supports 20mV to 50 Volts, Thermocouple Type: R, S, B, K, E, T, J, N and W and 4 Pulse or Logic Channels with Optional Cable (B-513)
- PC Connection through USB or LAN Ethernet Ports
- 7.0" TFT Colour LCD Display Shows Data in Waveform or Digital Format and Manage Logger Settings
- Ring Memory Function Allows for the Most Recent Data to be Saved to Internal Memory or External Device
- WLAN Compatible Using GL100-WL and Optional Wireless LAN Unit (B-568)
Spesification
Number of Channels | 20 Analog Signal Input Channels (Expandable to 200 Channels using Graphtec B-566 and B-564) |
Analog Input Terminals | Type: Multi-Input Type 1 Analog Input (20 Channels/terminal); Supports up to 10 Terminals |
Filter | Off, 2, 5, 10, 20, 40 (Moving Average in Selected Number) |
Input Method | All channels Isolated Balanced Input, Scans channels for sampling |
Type of Input Terminal | Screw Terminal (M3 Screw) |
Digital Sensor | 1 port for GL Digital Sensor |
External Inputs | Trigger or Sampling (1 Channel); Logic/Pulse (4 Channels) |
External Outputs | Alarm (4 Channels) |
Input Voltage (Max) | Between (+)/(-) Terminals: 60 Vp-p (20 mV to 2 Volts); 110 Vp-p (5 Volts to 100 Volts) Channels (-)/(-): 60 Vp-p Channel / GND: 60 Vp-p |
Max Voltage (Withstand) | Between Channels: 350 Vp-p (1 Minute) Channel / GND: 350 Vp-p (1 Minute) |
Measurement Ranges | Voltage: 20, 50, 100, 200, 500mV; 1, 2, 5, 10, 20, 50V; 1 to 5 Volts FS Thermocouple: Type K, J, E, T, R, S, B, N and W Supported RTD: PT100 (Spec IEC751), JPT100 (Spec JIS), PT1000 (Spec IEC751) Humidity: 0 to 100% (w/ Optional Graphtec B-530 Humidity Sensor) |
Measurement Accuracy | Voltage: • 0.1% Full Scale Type R Thermocouple: • 0°C ≤ TS ≤ 100°C: ±5.2°C • 100°C < TS ≤ 300°C: ±3.0°C • 300°C < TS ≤ 1600°C: ±(0.05 % of Rdg + 2.0°C) Type S Thermocouple: • 0°C ≤ TS ≤ 100°C: ±5.2°C • 100°C < TS ≤ 300°C: ±3.0°C • 300°C < TS ≤ 1760°C: ±(0.05 % of Rdg + 2.0°C) Type B Thermocouple: • 400°C ≤ TS ≤ 600°C: ±3.5°C • 600°C < TS ≤ 1820°C: ±(0.05% of Rdg + 2.0°C) Type K Thermocouple: • -200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C) • -100°C < TS ≤ 1370°C: ±(0.05% of Rdg + 1.0°C) Type E Thermocouple: • -200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C) • -100°C < TS ≤ 800°C: ±(0.05% of Rdg + 1.0°C) Type T Thermocouple: • -200°C ≤ TS ≤ -100°C: ±(0.1% of Rdg + 1.5°C) • -100°C < TS ≤ 400°C: ±(0.1% of Rdg + 0.5°C) Type J Thermocouple: • -200°C ≤ TS ≤ -100°C: ±2.7°C) • -100°C < TS ≤ 100°C: ±1.7°C) • 100°C < TS ≤ 1100°C: ±(0.05% of Rdg + 1.0 °C) Type N Thermocouple: • 0°C ≤ TS ≤ 1300°C: ±(0.1% of Rdg + 1.0°C) Type W Thermocouple: • 0°C ≤ TS ≤ 2000°C: ±(0.1% of Rdg + 1.5°C) Reference Junction Compensation: ±0.5°C Pt100 RTD Sensor: • -200°C ≤ TS ≤ 100°C: ±1.0°C • 100°C < TS ≤ 500°C: ±1.0°C • 500°C < TS ≤ 850°C: ±(0.05 % of Rdg + 2.0°C) JPt100 RTD Sensor: • -200°C ≤ TS ≤ 100°C: ±0.8°C • 100°C < TS ≤ 500°C: ±0.8°C Pt1000 RTD Sensor: • -200°C ≤ TS ≤ 100°C: ±0.8°C • 100°C < TS ≤ 500°C: ±0.8°C |
Sampling Interval | Voltage: 10ms (1 Channel), 20ms (2 Channels), 50ms (5 Channels), 100ms (10 Channels) 200ms-1 Hour (All Channels) Temperature: 100ms (10 Channels) 200ms-1 Hour(All Channels) |
Time Scale of Waveform Display | 1 second to 24 Hour/Division |
Trigger, Alarm Function | Trigger Action: • Start or Stop Capturing Data by the Trigger Repeat Action: • Off, On (Auto Rearmed) Trigger Source: • Start: Off, Measured Signal, Alarm, External, Clock, Week or Time • Stop: Off, Measured Signal, Alarm, External, Clock, Week or Time Combination: • OR or AND Condition at Level of Signal or Edge of Signal Condition Setting: • Analog: Rising, Falling, Window-in, Window-out • Pulse: (High), Falling (Low), Window-in, Window-out • Logic Signal: Pattern (Combination of Each Input Signal in High or Low) Alarm Output: • Outputs a Signal When Alarm Condition Occurs in the Input Signal |
Pulse Input | Accumulating Count Mode: • Number of Pulses from the Start of Measurement • Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS Instant Count Mode: • Counting the Number of Pulses per Sampling Interval • Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS Rotation Count (RPM) Mode: • Counting the Number of Pulses per second then Convert to RPM (Rotations per Minute) • Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS |
Calculation Function | Between Channels: Addition, Subtraction, Multiplication and Division for Analog Inputs Statistical: Select 2 Calculations from Average, Peak, Maximum, Minimum and RMS |
Search Function | Search for Analog Signal Levels, Values of Logic or Pulse or Alarm Point in Captured Data |
Interface to PC | Ethernet (10 Base-T/100 Base-Tx), USB (Hi-Speed), WLAN (using Graphtec B-568 Wireless Lan Adapter) |
Storage Devices | Media: SD Memory Card (SDHC up to 32GB), Supports 2 Slots Saved Contents: Captured Data, Setting Conditions, Screen Copy |
Capturing Mode | Mode: Normal, Ring, Relay Ring: Saves Most Recent Data (1,000 to 2 Million Readings) Relay: Saves Data to Multiple Files without losing data until Data Capturing is Stopped |
Replay Data | Replays Captured Data That Was Saved (BGD or CSV Format) |
Scaling Engineering Unit Function | Set Based on the Reference Point of the Scaled Output and Input Signal for Each Channel Analog Voltage: Converts using 4 Reference Points (Gain, Offset) Temperature: Converts using 2 Reference Points (Offset) Pulse Count: Converts using 2 Reference Points (Gain) |
Display | Size: 7.0" TFT Color LCD (WVGA: 800 x 480 pixels) Language: English, French, German, Chinese, Korean, Russian, Spanish and Japanese Information: Waveform in Y-T with Digital Values, Waveform Only, Digital Value, Digital Values and Statistics Values |
Action During Data Capture | Displaying past data (using Dual Display Mode - Current + Past Data) Hot-swapping the SD Memory Card Saving Data in Between Cursors |
Power Source | AC Adapter: 100 to 240 Volts AC, 50/60 Hz (1 pc of Adapter is Attached as Standard Accessory) DC Power: 8.5 to 24 Volts DC (Graphtec B-514 DC Power Cable is Required) Battery Pack: Mountable Battery Pack - 7.2 Volts DC, 2900mAh (Requires Graphtec B-569 Battery Pack) |
Power Consumption | Max. 38 VA |
A/D Converter | ΣΔ Type; 16 Bits (Effective Resolution: 1/40,000 of Full Range) |
Operating Environment | Temperature: 0 to 45°C Humidity: 5 to 85% RH (Non-condensing) |
OS Compatibility | Windows 8.1, 8.0, 7, Vista and XP (32 and 64 Bit Editions) |
Weight | 1010 grams (35.63 ounces) |