Phone

0813 9929 1909 (Fikri)

0823 1234 7066 (Rizki)

Phone Office

+62-21 29563045





×


SRP-003-128K 8 Channel AC Current, Voltage and Temp Data Logger *SPECIAL*


Hubungi Kami






Description

  • Measure & Record AC Current, Voltage and Temperature
  • 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
  • Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
  • 32KB Memory and Data Storage
  • 25/Second to 8 Hour User-Selectable Sampling Rate
  • 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)

Feature

Requires ACR TrendReader 2 Software and USB Cable Kit


Spesification

Channels8
(1) Internal Temperature and (7) 0 to 5 Volts DC Inputs for Current Transducers or Single/Three Phase Voltage TransducersTemperatureSensor Type: NTC Thermistor - 10,000 Ohms @ 25°C
Range: -40°C to 70°C (-40°F to 158°F)
Accuracy: ±0.2°C (±0.3°F) @ 0°C to 70°C
Resolution: 0.03°C (0.5°F) @ 25°CVoltageRange: 5 to 240 Amps
Accuracy (5 to 10A): 3.0% of Reading ± 100mV
Accuracy (10 to 40A): 2.5% of Reading ± 50mV
Accuracy (40 to 100A): 2.0% of Reading ± 50mV
Accuracy (100 to 240A): 2.0% of Reading
Resolution: 0.03°C (0.5°F) @ 25°CCurrentRange: 0.5 to 250 Amps (with Current Probe #CT-253)Resolution12-Bit (1 Part 4096)Data Storage Capacity87,000 Readings Sampling Rate25/Second to 8 Hours
Note: Battery Pack (#BP-101) or Power Supply (#PS-201) Required for Sampling Rates Faster than 8/SecondClock Accuracy ±2 Seconds per DayOperating ModesContinuous (FIFO) or Stop When Full (Fill then Stop)Operating RangeTemperature: -40°C to 70°C (-40°F to 158°F)
Humidity: 0 to 95% RH (non-condensing)Power Source3.6V 1Amp-Hour Lithium Battery (Factory Replaceable)Battery Life10 Year (Normal Use)
Dependant Upon Environment and Sampling RatePower Consumption5 to 10 microamps (Continuous)Product ApprovalsMeets Part 15 for Digital Devices of the Code of Federal
Regulations of the Federal Communications Commission
(FCC). Meets radiated and conducted emission require
ments for the Interference Causing Equipment Standard f
or Digital Apparatus of Industry Canada (ICES-003).
IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity,
EFT/Burst and Radiated Emissions respectively for the
Commission of the European Communities (CE)Resistance to X-RaysTested for protection against a 160kV dose @ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine). Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object
distance 5”Communication TypeUSB or RS-232 Port
(Requires #TR2-USB or TR2-RS232 TrendReader Software Package)HousingNoryl PlasticMountingMagnetic Backing or Locking EyeletOS CompatibilityWindows 8, 7 (32-bit and 64-bit), Vista (32-bit) and XP (SP3)Standards ComplianceCEWeight3.75 oz (110 grams)Dimensions4.2" x 2.9" x 0.9" (10.7cm x 7.4cm x 2.2)