U24-002-C Saltwater Conductivity and Salinity Data Logger


Hubungi Kami





Description

HOBO U24-002-C adalah data logger hemat biaya untuk mengukur kadar garam, konduktivitas dan suhu di lingkungan air asin dengan perubahan salinitas yang relatif kecil (± 5.000 μS / cm) seperti teluk air asin, atau untuk mendeteksi kejadian salinitas seperti pemanasan , hujan badai, dan kejadian pelepasan. Hal ini juga dapat digunakan untuk mengumpulkan data salinitas untuk kompensasi salinitas data logger Oksigen HOBO U26.


Feature

  • Non-contact Sensor Minimizes Drift-Related Measurement Errors
  • Also Features Open Access to Sensor for Cleaning and Software-Based Drift Compensation
  • Software Enables Start/End-Point Calibration to Compensate for Fouling and Easy Conversion to Specific Conductance and Salinity
  • 1,000 to 55,000 µS/cm (Conductivity Extended Range) and 5°C to 35°C (Temp) Measurement Ranges
  • 3 Year Battery Life with Factory Replaceable Battery
  • Stores at Least 14,400 Sets of Measured Readings
  • Requires HOBOware Pro Software (Version 3.2+)

Spesification

Data Channels 2 Channels (Conductivity or Salinity and Temperature)
Conductivity
(Salinity)
Calibrated Low Range: 100 to 10,000 µS/cm @ 5°C to 35°C)
Calibrated Full Range: 5000 to 5,000 µS/cm @ 5°C to 35°C)
Resolution: 2 µS/cm
Accuracy (Low Range): 3% of Reading, or 50 µS/cm
Accuracy (High Range): 5% of Reading*
Drift: Up to 12% per month in saltwater (exc. drift from fouling)
* In waters within a range of 3,000 µS/cm
Temperature Measurement Range: 5°C to 35°C (41°C to 95°F)
Resolution: 0.01°C (0.02°F)
Accuracy: 0.1°C (0.2°F)
Response Time 1 second to 90% of Change (In Water)
Data Storage Capacity 1 Conductivity Range: 18,500 Measurement Readings
2 Conductivity Ranges: 14,400 Measurement Readings
Sampling Rate 1 Second to 18 Hours (User-Specified)
Up to 8 Sampling Intervals User-Defined
Operating Range Temperature: -2°C to 36 °C (28°F to 97°F) - Non-Freezing
Battery 3.6 Volt Lithium Battery - Factory Replaceable Only
Battery Life 3 Years @ 1 Minute Sampling Rate 
(Dependant Upon Environment and Operating Range)
Maximum Depth 70 Meters (225 feet)
Sample & Event Logging Samples: Recorded Sensor Measurements
Events: Logger Activity (ie: Bad Battery, Host Connected)
Wetted Housing Materials Delrin, Epoxy, Stainless Steel Retaining Ring, Polypropylene, Buna Rubber O-Ring, Titanium Pentoxide (Inert Coating Over Sensor)
Note: All Materials Are Suitable for Long-Term use in Saltwater
Communications USB optical Interface for Downloading Data. Requires Base Station (U-DTW-1 or BASE-U-4)
Software Compatibility HOBOWare Pro Version 3.2+
OS Compatibility Windows: Windows 8, 7, Vista and XP (32-Bit and 64-Bit)
Mac: OS X 10.6.x, 10.7.x and 10.8.x
Standards Compliance CE
Weight 193 grams (6.82 oz.)
Buoyancy in Freshwater: -59.8gm (-2.11 oz.)
Dimensions 3.18cm x 16.5cm (1.25" x 6.5")
Mounting Hole: 6.3mm (0.25")